03.02.2026 by Aileen Sammler

From Kinetic Model to Real-World Application: How NETZSCH Termica Neo Simulates Thermal Reactions

3D temperature distribution model illustrating conversion rates in thermal simulations for chemical processes using Termica Neo software.

This blog article is the first of our five-part series “The New Dimension of Thermal Analysis with NETZSCH Termica Neo: Software for the Thermal Simulation of Chemical Reactions on an Industrial Scale.”

Stay tuned and read about the following topics over the next few weeks: From the Kinetic Model to Real-World Applications; Scale-up & Safety; Polymer Curing; Thermoplastic CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.Crystallization (PA12); Ceramic SinteringSintering is a production process for forming a mechanically strong body out of a ceramic or metallic powder. Sintering

Termica Neo logo for thermal simulation software in the chemical industry, emphasizing advanced analysis and safety.

Introduction: When Curves Become Reality

Every thermal process tells a story of energy, reactivity, or transformation. Until now, this story has been conveyed through one-dimensional curves: reaction rate vs. time, conversion vs. temperature. But what if you could see how these reactions unfold inside your material in three dimensions?

With NETZSCH Termica Neo, that vision becomes a reality. It bridges the gap between experimental kinetics and real-world applications, turning measured data into dynamic thermal fields you can explore, analyze, and optimize.

Termica Neo is a software program designed for the simulation of the thermal behavior and thermal safety in chemical reactions and CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization in solids or liquids. It operates in volumes with characteristic size ranging from centimeters to meters. Termica Neo’s primary applications involve materials characterized with elevated thermal potential, in conjunction with reactions such as Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing, cross-linking, SinteringSintering is a production process for forming a mechanically strong body out of a ceramic or metallic powder. sintering, Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition, and polymer CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization.

3D temperature field simulation with colored hotspots and conversion zones illustrating thermal behavior in reactive materials.
Figure: 3D simulation of temperature fields – colored cross-section showing local hotspots and conversion zones.

Why 1D Analysis Is Not Enough

In classic DSC, DIL, Accelerating Rate Calorimetry (ARC)The method describing isothermal and adiabatic test procedures used to detect thermally exothermic decomposition reactions.ARC® or TGA measurements, we observe reactions at a given temperature. We see a curve that hides sample size, shape and the local story. However, in real-world applications, temperature, heat production and reaction fronts never behave uniformly:

These are the effects that determine product quality, safety, and performance; yet until now, they were invisible. That is where the NETZSCH Termica Neo software comes into play.

3D geometry setup interface for NETZSCH Termica Neo, showcasing customizable shapes and container properties for thermal analysis.
Figure: Geometry-setup interface with selectable shapes (plate / cylinder / sphere / rotational body).

Introducing Termica Neo: The Simulation Software for Thermal Analysis

Termica Neo extends the power of thermal analysis from data to simulation. It directly imports kinetic models from the NETZSCH Kinetics Neo Software, whether they are model-free or model-based, single-step or multi-step, autocatalytic or diffusion-controlled.

Once the kinetics data has been loaded, you can additionally define:

The result is a virtual laboratory, where complex reactive behavior can be simulated in 2D or 3D geometries such as plates, cylinders, spheres, or rotational bodies.

From Data to Dynamic Fields

Once launched, Termica Neo computes temperature, conversion, conversion rate, and concentration distributions over the entire volume of your sample, not just over time.

Interactive 2D and 3D views allow you to rotate, slice, and zoom into the process. Hotspots become visible. Reaction fronts move before your eyes. The results can be exported as heat maps, 3D renders, or AVI animations for reporting and communication purposes.

3D thermal simulation visuals showcasing temperature distribution patterns, highlighting hotspots for chemical reaction analysis with NETZSCH Termica Neo.
Figure: Sequence of temperature and conversion heatmaps showing front propagation through a plate.

Impact on R&D and Industry

With the NETZSCH Termica Neo software, the measurement curve becomes a predictive simulation tool:

This approach is faster, safer, and far more insightful than traditional “trial and error.”

Imagine being able to validate your Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing, SinteringSintering is a production process for forming a mechanically strong body out of a ceramic or metallic powder. sintering or Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition behavior at the press of a button. That’s what the NETZSCH Termica Neo software delivers.


Download the new brochure to find out more:

What You can Do with Termica Neo

About This Blog Series

This article is the first article in our five-part blog series: “The New Dimension of Thermal Analysis with NETZSCH Termica Neo: Software for the Thermal Simulation of Chemical Reactions on an Industrial Scale.” 

In the upcoming posts, we’ll dive deeper into:

Stay tuned! Each article stands on its own, but together they reveal how Termica Neo transforms thermal analysis from data collection to true thermal intelligence.

--------------------------

Useful links:

Get your free demo version:Request Demo Version of Temica Form - NETZSCH Termica Neo

Direct contact:Feature Request - NETZSCH Kinetics Neo

Learn even more:Termica Neo - NETZSCH Termica Neo

Watch also this Webinar: