NETZSCH Kinexus Prime DSR+, a sophisticated rheometer for advanced material analysis and testing in laboratories.
Rheology

Kinexus Prime DSR+

Redefining Rheometer Capabilities for Asphalt Binder and Bitumen Testing

Highlights

The world's most sensitive DSR for all construction and petro chemicals testing

The Kinexus Prime DSR+ is a dynamic shear rheometer specifically designed for research and development requirements in the asphalt industry. With its true "plug and play" functionality for all measurement systems and environmental control units, it offers ease of use. The Kinexus DSR+ enables innovative standard operating procedure (SOP)-based testing while providing access to a comprehensive range of standard rheological tests with complete flexibility in test design and set-up.

The device offers precise torque control thanks to an ultra-light, electronically commutated motor. This enables rapid changes in torque and speed as well as access to higher oscillation frequencies without extensive adjustments. The wide torque range allows measurements from low-viscosity liquids to solids without changing test conditions or measurement geometries. Intelligent motor cooling regulates the operating temperature according to torque and power requirements.

Provideing frictionless support between moving parts through sintered, porous carbon for even air distribution and enables torques below 1 nNm. High axial and radial stiffness increases robustness and reduces compliance.

Precision measurement of rotor position and speed:

Connection and alignment of the measuring system with the motor and bearing unit:

  • Quick connection mechanism enables easy insertion and removal of the measuring systems while maintaining micrometer alignment.
  • Automatic recognition by RFID (Radio Frequency Identification) records measuring systems, calibration constants and operating settings and ensures that a zero position is reached before measurement.

Transmission of torque or movement from the motor unit to the specimen:

  • Versatile measuring systems such as plates, cones, cylinders and vanes in various sizes, materials and surfaces.
  • Precision mechanics for exact rheological measurements with high shaft stiffness and low mass to minimize compliance and inertia.
  • Quick connection system and integrated RFID recognition shorten the preparation time and ensure the correct use of the measuring system and calibration constants.

Enables measurement and control of the normal force:

Controlled vertical profiles for sample loading and axial testing 

  • Enables full range of vertical profiles including linear, exponential and normal force over a working range of 230 mm (0.1 μm resolution) and speed range of 0.1 μm/s to 35 mm/s for controlled sample loading or dedicated axial testing

Contains all electronic components for controlling the rheometer:

  • Microelectronics in close proximity to the measurement improves quality and reliability.
  • Integrated control and measurement functions with fast digital signal processor (DSP) for intelligent device function.

Enables quick lower geometry replacement and temperature/ambient control through:

  • Unique plug-and-play cartridge system with automatic detection for all connections with a single handle.
  • Various cartridge options including asphalt peltier plate, universal cylinder and high temperature design.
  • Geometries available in various sizes, materials and finishes.
  • Simple mounting and removal mechanism for the lower measuring system with micrometer alignment maintained.
  • Use of Peltier elements to heat/cool the top and bottom plates for improved efficiency.
  • Optimally placed temperature sensors (PT100) for fast and accurate sample temperature measurement.

Enables direct control of rheometer functions from the device through:

  • Control panel functionality linked to user instructions in test sequences for easy interaction without a keypad.
  • Warning lights for rheometer errors, software communication errors or low air bearing pressure.
  • Robust, solvent-free design for glove operation and easy cleaning.

Rotational Rheology Uncovered: A Five-Part Webinar Series

Explore the fundamentals and advanced applications of rotational rheology in this expert-led webinar series. Learn how to characterize flow behavior, optimize measurements, and gain confidence in your rheological results.

Explore All Webinars

Our Quality Promise:

NETZSCH’s Unlimited Warranty

At NETZSCH, our commitment to quality goes beyond the instruments themselves. We understand that your investment in advanced technology is a long-term one, and and that’s why we offer something truly unique – our Unlimited Warranty.

Method

The rotational rheology is a measurement method for determining the flow and deformation properties of materials using rotational movements. A sample is placed between two plates or in a cylindrical measuring system (e.g. a cone-plate system) and subjected to a rotating shear force. By analyzing the resulting shear StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress and shear rate, important rheological parameters such as viscosity, elasticity and yield point can be determined. This method is particularly useful for the characterization of liquids, gels, pastes and soft solids in various scientific and industrial applications.

Close-up of teal liquid forming a droplet under a metallic apparatus, illustrating fluid dynamics in a scientific context.

Specifications

 Kinexus Prime DSR+
Torque range – viscometry5 nNm – 225 mNm
Torque resolution0.1 nNm
Angular velocity range1 nrads-1 to 500 rads-1
Frequency range

6.28 μrads-1 to 942 rads-1

(1 μHz to 150 Hz)

Normal force range0.001 N - 50 N
Vertical lift speed0.1 μms-1 to 35 mms-1

Measuring Systems and Accessories

Peltier-Plate Cartridge with Active Hood, designed for temperature testing from -40°C to 180°C, showcasing precise heating elements.
Peltier-Plate Cartridge with Active Hood (-40°C to 180°C)
Peltier-cylinder cartridge designed for temperature range of -25°C to 200°C, featuring an ergonomic handle for easy use.
Peltier-Cylinder Cartridge (-25°C to 200°C)
HTC Prime Cartridge for precise temperature testing (5°C to 450°C) in laboratory analysis and material testing applications.
HTC Prime Cartridge (5°C to 450°C)
Customer support representative at a computer, smiling and engaged, highlighting NETZSCH's commitment to service excellence.


Proven Excellence in Service

At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime. 

Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.

Software

rSpace can be used for simple QC operationor for advanced rheological testing

  • Constant feedback and user guidance
  • Guarantee of optimal rheological processes
  • Integration of specific test controls relevant to your samples
  • Development of standard test methods for your samples
  • Available for company-wide use
  • Standardizes consistent, operator-independent tests
  • Application of time-temperature superposition to create master curves
  • Automatic scoring as "pass" or "fail" based on the appropriate test criteria
  • Report design with automatic print and PDF creation options
TGA analysis of polycarbonate shows thermal decomposition starting at 350°C, with total ion current peaks from 450°C to 550°C.

E-Learning

Become an Expert with our Free E-Learning Courses

All NETZSCH E-Learning Basic Courses are free of charge! The content is created by our laboratory method experts, who share their personal experiences with you. Take advantage of flexible online learning, fully adapted to your training needs!

Please accept Marketing Cookies to see that Video.

A red Formula 1 racing car in the pit, surrounded by team members in orange and red, preparing for a quick tire change.