DSC 3500 Sirius thermal analysis instrument features high sensitivity and a wide temperature range for material characterization.
differential scanning calorimetry

DSC 3500 Sirius

Differential Scanning Calorimeter

The cost-effective starter instrument for material characterization

The DSC 3500 Sirius unites state-of-the-art technology with high sensitivity in a robust, easy-to-operate measuring system across a temperature range from -170°C to 600°C. The most important characteristics of the DSC 3500 Sirius measuring cell are its silver furnace with long-life heating element and its monolithic DSC sensor featuring high stability and optimal resolution.

For high sample throughput, we recommend that the unit be equipped with an automatic sample changer (ASC) – this accommodates up to 20 samples and references, even of different crucible types.

The design of the DSC 3500 Sirius developed in Japan is tailored to routine tasks in quality control and failure analysis as well as for material characterization of technical textiles, of food products, in packaging, in the polymer and cosmetic industry and for further organic or inorganic materials.

Request a Quote

Get a personalized offer now.

Request a Quote

Technical Data

Temperature range
-170°C to 600°C
Heating rates
0.001 K/min to 100 K/min
Cooling rates
0.001 K/min to 100 K/min
(depending on temp.)
DSC 3500 Sirius thermosystem with automatic sample changer, designed for material characterization from -170°C to 600°C.

Sensor:
heat flux system

Measurement range:
± 650 mW

Temperature accuracy:
0.1 K

Enthalpy accuracy:
generally < 2%

Atmospheres:
oxid., inert (static, dynamic)

Automatic sample changer (ASC)
for up to 20 samples and references (optional)

Thermal conductivity test results displayed on computer software alongside printed data analysis from NETZSCH, showcasing measurement graphs and tables.

The DSC 3500 Sirius runs underProteus® Software on Windows®. The Proteus® Software includes everything you need to carry out a measurement and evaluate the resulting data. Through the combination of easy-to-understand menus and automated routines, a tool has been created that is extremely user-friendly and, at the same time, allows sophisticated analysis. The Proteus® Software is licensed with the instrument and can of course be installed on other computer systems.

DSC features:

You can use the following software with this product

The DSC 3500 Sirius can be equipped with various accessories and extensions for optimum adjustment of the system to your requirements. Various cooling systems (forced air via compressor or pressurized air) can be used to cool the furnace back to room temperature. The liquid nitrogen cooling system allows tests at subambient temperatures from -170°C up to 600°C.
The cost-efficient intracooler IC40 offers an alternative to liquid nitrogen cooling and makes it possible to run measurements between -40°C to 600°C.

The more powerful intracooler IC70 ensures faster cooling rates and enables working within a temperature range between -70°C and 600°C.

All cooling options can be upgraded to the DSC 3500 Sirius.

For investigation of the oxidative stability (e.g. Oxidative-Induction Time, Oxidative-Induction Time (OIT) and Oxidative-Onset Temperature (OOT)Oxidative Induction Time (isothermal OIT) is a relative measure of the resistance of a (stabilized) material to oxidative decomposition. Oxidative-Induction Temperature (dynamic OIT) or Oxidative-Onset Temperature (OOT) is a relative measure of the resistance of a (stabilized) material to oxidative decomposition.OIT), the DSC 3500 Sirius can be equipped with a software-controlled MFC gas flow control system for three gases.

Various crucibles and lids for the DSC 3500 *Sirius*, including materials like stainless steel and aluminum, for diverse applications.
A wide range of crucibles and pans (aluminum, copper, silver, platinum, stainless steel for pressure applications, etc.) is available for nearly all possible applications and materials.
NETZSCH SampleCutter with adjustable jaws, designed for efficient preparation of hard materials like fiberglass-filled granulates.
With the NETZSCH sample preparation set and the SampleCutter, even hard or brittle materials such as fiberglass-filled granulates or small components can be prepared in no time.
Sealing press for cold-weldable aluminum and stainless steel crucibles, designed for pressures up to 20 bar. Ideal for material testing.
For the sealing press exchangeable inserts are available, for all cold-weldable aluminum crucibles/pans and stainless steel crucibles for pressures up to 20 bar (Photo).
NETZSCH employees celebrate 150 years at a festive Munich event, engaging warmly and exchanging greetings outdoors.
Routine applications are facilitated conveniently with an automatic sample changer (ASC) for up to 20 samples and reference materials, also for different crucible types.

Standard Crucibles Made of Aluminum for the DSC 3500 Sirius

Material
Temperature
Range (Max.)
Consisting ofDimension/
Volume
RemarksOrder Number
Al600°CCrucible + lidø 6 mm/
25/40 μl*
Set of 100/500 pcs,
cold weldable**
6.239.2-64.5.00/
6.239.2-64.51.00
Al600°CCrucible + lid
with laser-cut hole
(50 μm)
ø 6 mm/
40 μl
Set of 100/500 pcs,
cold weldable**
6.239.2-64.8.00/
6.239.2-64.81.00

Crucibles for General and Special Applications – DSC 3500 Sirius

Material

Temperature
Range (Max.)
Consisting ofDimension/
Volume/Pressure
RemarksOrder Number
Al600°CConcavus®pan + lidø 5mm/
30/40 μl
Set of 96 Concavus® pans and lids incl. 3in1 Box,
cold weldable*
DSC21400A66.010-00
Cu600°CCrucibleø 6 mm/
25/40 μl
For Oxidative-Induction Time (OIT) and Oxidative-Onset Temperature (OOT)Oxidative Induction Time (isothermal OIT) is a relative measure of the resistance of a (stabilized) material to oxidative decomposition. Oxidative-Induction Temperature (dynamic OIT) or Oxidative-Onset Temperature (OOT) is a relative measure of the resistance of a (stabilized) material to oxidative decomposition.OIT measurements according to
ASTM D3895,
Set of 25
6.239.2.-64.6.00
CrNi steel250°CCrucible + lid + elastomer seal120 μl/
20 bar
Set of 25 pieces6.240.1-68.1.00
CrNi steel500°CCrucible + lid, gold-plated surface, reusableø 6mm/
27 μl/
max. 100 bar
10 crucibles + 50 Au sealing disks***6.239.2-92.31.00
CrNi steel500°CCrucible + lid, gold-plated surface, reusableø 6mm/
100 μl/
max. 100 bar
1 crucible + 5 Au sealing disks***6.239.2-92.8.00
Titanium500°CCrucible + lid, reusableø 6 mm/
27 μl/
max. 100 bar
1 crucible + 5 Au sealing disks***6.239.2-92.6.00
Titanium500°CCrucible + lid, reusableø 6 mm/
100 μl/
max. 100 bar
1 crucible + 5 Au sealing disks***6.239.2-92.9.00
Al2O31700°CCrucibleø 6.8 mm/
85 μl
GB399972
Al2O31700°CLidFor GB399972GB399973
Pt/Rh1700°CCrucibleø 6.8 mm/
85 μl
GB399205
Pt/Rh1700°CCrucibleø 6.8 mm/
190 μl
NGB801556
Pt/Rh1700°CLidFor GB399205 and NGB801556GB399860

* Crucible volumes of either 25 μl or 40 μl can be achieved by simply reversing the lid.
** One and the same sealing press is capable of sealing all standard Al crucibles; order no. 6.240.10-80.0.00A.
*** Sealing tool order no. 6.239.2-92.4 required.

Other crucibles and number of pieces per set are available on demand.