The STA 449 F1 Jupiter® combines unlimited configuration flexibility and unmatched performance in just one instrument.
- Thermal stability, Reakcja rozkładu (dekompozycji)A decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition behavior, composition, Phase TransitionsThe term phase transition (or phase change) is most commonly used to describe transitions between the solid, liquid and gaseous states.phase transitions, melting processes to be analyzed comprehensively and quickly
- Easily to use top-loading system with exceptionally precise balance resolution (25 ng resolution at a weighing range of 5g) and highest long-term stability
- Interchangeable sensors for DSC measurements with highest sensitivity and best reproducibility for reaction/transition temperatures and enthalpies as well as for measurements of specific heat (videoclip for sensor exchange)
- A variety of optional system enhancements for ideal system adaption to user-defined applications
- Various furnaces, easily interchangeable by the user, available (optional a swiveling double hoisting device for two furnaces) - please see accessories
- Pluggable sample carriers (TGA, TGA-DSC, TGA-DTA, etc.)
- Automatic Sample Changer (ASC) for up to 20 samples
- Automatic evacuation and refilling (AutoVac)
- Plenty of accessories, e.g. sample crucibles in the most varied of forms and materials
- Unique for STA: temperature-modulated DSC (TM-DSC)
By supplementary MS and/or FT-IR coupling even more comprehensive analyses are possible.
All these features make the new developed STA 449 F1 Jupiter® the ideal tool for thermal analysis of materials in the fields of research, developments and quality assurance.

Request a Quote
Dane techniczne
Temperature range
-150°C to 2000°C
High-speed furnace
RT to 1250°C
Heating and cooling rates
0.001 K/min to 50 K/min
(dependent on furnace)
(dependent on furnace)

Weighing range:
5000 mg
TGA resolution:
0.025 µg
DSC resolution:
< 1 µW (dependent on sensor)
Atmospheres:
inert, oxidizing, reducing, static, dynamic, vacuum
Integrated mass flow controller:
for 2 purge gases and 1 protective gas
Vacuum-tight assembly:
up to 10-4 mbar (10-2 Pa)
Literatura przedmiotu

Product Information
Wideo
STA 449 F1 Jupiter® EN
Thermal Analysis: Cutting Edge Technology by NETZSCH
NETZSCH STA 449 F1 Jupiter® for Simultaneous Thermal Analysis
Webcast: Part 2 Sample Preparation Influencing Factors How to Setup an STA Measurement