Explore the range of NETZSCH DSC instruments 

Explore the range of NETZSCH STA instruments 

  • STA 509 Jupiter® Classic

    Best Price/Performance Ratio

    • RT to 1600°C
    • SiC furnace
    • Balance resolution: 0.1 μg
    • Optional 20-position ASC
  • STA 509 Jupiter® Select

    Tailored to Your Needs

    • -150 to 2400°C
    • Choice of 12 different furnaces
    • Balance resolution: 0.1 μg
    • Optional 20-position ASC or 2nd furnace
  • STA 509 Jupiter® Supreme

    Instrument for Highest Performance

    • -150°C to 2000°C
    • Choice of 9 different furnaces
    • Balance resolution: 0.025 μg
    • Optional 20-position ASC or 2nd furnace
  • H₂Secure

    Safely examine materials under hydrogen

    • Accessory for the STA 509 Jupiter® series and the TMA 512 Hyperion® series
    • Retrofittable for the STA 449 Jupiter® series
  • STA 2500 Regulus

    A Highly Reliable and Fully Equipped Cost-Saving Instrument Package 

    • RT to 1600°C
    • Temperature precision: 0.3K
  • PERSEUS® STA 509 Jupiter®

    The Revolution in STA-FT-IR Coupling 

    • No liquid nitrogen required
    • No separate transfer line
    • Space saving design
    • Easy operation with automatic sample changer
    • Evolved gas analysis up to 2000 °C sample temperature

Explore the Range of NETZSCH TG instruments

  • TG 309 Libra® Classic

    Ensure product quality by detecting mass changes with the perfect thermobalance for quality control!

    • Balance Resolution: 50ng
    • Temperature range: RT (10°C) to 1025°C at the sample
    • Automatic Sample Changer: 20 sample and reference spaces
  • TG 309 Libra® Select

    Our work horse for testing in laboratories, including industrial development labs!

    • Balance Resolution: 20ng
    • Temperature range: RT (10°C) to 1025°C/1100°C at the sample
    • Automatic Sample Changer: 204 sample and reference spaces
  • TG 309 Libra® Supreme

    Ensure product quality and safety with the all-in-one instrument for research labs in academia and industry!

    • Balance Resolution: 10ng
    • Temperature range: RT (10°C) to 1100°C at the sample
    • Automatic Sample Changer: 204 sample and reference spaces

Explore the range of NETZSCH DMA instruments 

  • DMA 303 Eplexor®
    • Wide temperature range from -170°C to 800°C
    • Precise forces up to 50 N dynamic and static
    • Accessories for multiple measuring modes and a variety of sample holders
  • DMA 503 Eplexor®
    • Temperature range from -160°C to 500°C
    • Dynamic forces up to ±500N
    • Static forces up to 1500N
  • DMA 503 Eplexor® HT
    • Temperature range from -160°C to 1500°C
    • Dynamic forces up to ±500N
    • Static forces up to 1500N
  • DMA 523 Eplexor®
    • Temperature range from -160°C to 500°C
    • Dynamic forces up to ±4000N
    • Static forces up to 6000N
  • HBU 523 Gabometer

Explore the range of NETZSCH DIL instruments 

  • DIL 502 Expedis® Classic

    Designed for industrial applications

    • 3 Furnaces for temperatures from RT to 1600°C
    • Resolution: 2 nm
    • Measurement range: ± 5mm
    • Gas-tight
  • DIL 502 Expedis® Select

    Designed for sophisticated industrial research and contract laboratories

    • 7 Furnaces for temperatures from -180°C to 2000°C
    • Resolution: 1 nm
    • Measurement range: ± 10 mm
    • Vacuum-tight
  • DIL 502 Expedis® Supreme

    Designed for high-end research & development

    • 9 Furnaces for temperatures from -180°C to 2800°C
    • Resolution: 0.1 nm
    • Measurement range: ± 25mm
    • Vacuum-tight
  • DIL 402 Expedis® Classic

    State-of-the-art dilatometer technology

    • MultiTouch feature for an exact sample position
    • NanoEye - Unrivaled Dimension in Measuring Range and Accuracy
    • Pushrod dilatometer with furnaces up to 1600°C
  • DIL 402 Expedis® Select
    • Temperature Range: -180°C to 1600°C
    • double furnace sliding carrier
    • ΔL Resolution over the entire measuring range: 1 nm
  • DIL 402 Expedis® Supreme
    • Temperature Range: -180°C to 2000°C
    • double furnace sliding carrier
    • ΔL Resolution over the entire measuring range: 0.1 nm

Explore the range of NETZSCH LFA instruments 

Explore the range of NETZSCH HFM and GHFM instruments 

Explore the range of NETZSCH Kinexus Prime instruments 

  • Kinexus Prime ultra+

    High-end rheometer for highest demands

    • Torque range - viscometry: 1.0 nNm to 250 mNm
    • Torque range - oscillation: 0.5 nNm to 250 mNm
  • Kinexus Prime pro+

    For research and development

    • Torque range - viscometry: 5.0 nNm to 225 mNm
    • Torque range - oscillation: 1.0 nNm to 225 mNm
  • Kinexus Prime lab+

    Rotational Rheometer for Quality Control with SOP

    • Torque range - viscometry: 5.0 nNm to 200 mNm
    • Torque range - oscillation: 5.0 nNm to 200 mNm
  • Kinexus Prime DSR+

    The world's most sensitive DSR for all construction and petro chemicals testing

    • Dynamic Shear Rheometers for Asphalt Binder and Bitumen Testing
    • Torque range - viscometry: 5 nNm to 225 mNm
    • Torque range - oscillation: 1 nNm to 225 mNm
  • Kinexus Prime DSR

    A diverse analytical research solution for laboratory testing

    • Dynamic Shear Rheometers for Asphalt Binder and Bitumen Testing
    • Torque range - viscometry: 10 nNm to 200 mNm
    • Torque range - oscillation: 5 nNm to 200 mNm
  • Kinexus Prime DSR-III

    Complete package for routine QA/QC paving analysis

    • Dynamic Shear Rheometers for Asphalt Binder and Bitumen Testing
    • Torque range - viscometry: 100 nNm to 150 mNm
    • Torque range - oscillation: 100 nNm to 150 mNm

Explore the range of NETZSCH Rosand instruments 

  • Rosand RH2000

    Bench-top capillary rheometer

    • single and twin-bore
    • maximum force: 12 kN (20 kN option)
    • frame stiffness: 100 kN
  • Rosand RH7/RH10

    Floor-standing capillary rheometer

    • twin-bore
    • maximum force: 50 kN for RH7, 100 kN for RH10
    • frame stiffness: 250 kN