Published on 

Protect Your Plastic Products: Why Cars Can Be a Risk on Hot Summer Days

Part 1 – Influence of Repeated Extrusion Processing on the Creep Behavior of PE-HD Polymers

Introduction

Polymers have become indispensable in many areas of our lives including the packaging industry, offering versatile solutions such as films, sheets, bottles and foam containers. Their light weight, durability, and adaptability make them ideal for transporting, protecting and preserving products across various sectors. One such application is the use of bi-modal high-DensityThe mass density is defined as the ratio between mass and volume. density polyethylene (PE-HD) in detergent bottles, as its unique molecular structure provides an excellent balance of strength, durability, and environmental StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress crack resistance, ensuring reliable performance during storage and handling. Currently, most industries are facing increasingly stringent restrictions on recycling quotas and CO2 emission targets. In the European Union, the so-called “Green Deal” sets a target that 55% of all plastic packaging waste should be recycled by 2030 [1]. Polymer product engineers are therefore facing the challenge of manufacturing with the required portion of recyclates while still fulfilling the quality standards of their customers.

Among the polymers most commonly used as post-consumer recycled (PCR) polymers are thermoplastics such as polyethylene (PE), polypropylene (PP) or polyethylene terephthalate (PET) [2]. Thermoplastics allow for easy recycling by remelting the material and repeatedly processing it into the desired final shape. However, the use of PCR polymers does not come without any disadvantage. During processing (e.g., injection molding), materials such as PE exhibit two distinct degradation processes [3]: Chain scission and crosslinking due to recombination of polymer chain parts. Furthermore, a thermo-oxidative degradation can occur.

Importantly, the effect of these degradation mechanisms may not affect the relevant mechanical properties in the same way. Depending on which of these reactions dominates during reprocessing, the changes in mechanical properties will be different for each specific situation. For example, an increase in Young’s modulus or a decrease in elongation at break is observed when Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.crosslinking reactions dominate. Likewise, a scission reaction may produce the opposite outcome. Therefore, the individual properties must be studied separately, depending on the application of the final product [3].

In the following, the CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep behavior of a bi-modal PE-HD polymer typically used in detergent bottles was investigated using the DMA 303 Eplexor®®. The difference between each of the three PE-HD samples is the number of extrusion cycles the material has undergone. Here, PE-HD polymers that have been extruded once (x1), three times (x3) and seven times (x7) are compared.

Creep

CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.Creep is the permanent, time-dependent deformation at elevated homologous temperatures, which is the temperature, T, normalized on the Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point,Tm, of the material,

Equation illustrating the relationship in data analysis, featuring variables T, Thom, and Tm.

caused by a constant applied StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress below the elastic limit. Because semicrystalline polymers have rather low melting points, their homologous temperature in service, even at room temperature, is relatively high compared to other material classes such as metals or ceramics. This fact requires designers of polymer products to be aware of this deformation mode, as it can lead to undesirable consequences if the CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep behavior of the material is not well understood. An illustrative example is shown in figure 1, which displays the bottom of a PET plastic bottle. Here, the polymer deformed under the increasing pressure of the air trapped inside the bottle due to the elevated temperatures that occur in a car in summer. Both factors resulted in permanent deformation of the reusable plastic bottle, rendering it unusable for its intended reuse.

During CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep, materials undergo three distinct stages, referred to as primary, secondary or steady-state and tertiary CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep.

Warped reusable plastic bottle cap, showing deformation from heat exposure in a hot car during summer.
1) Image of a reusable plastic bottle left for too long in a hot car in summer.

When StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress is applied, the material will immediately deform elastically according to the Young’s modulus of the material. As time increases, the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate decreases until it reaches the second stage, where the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate remains constant. Once a threshold StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain is reached, the material tends to start necking. This causes a local increase in StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress that further accelerates the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate until the material fails [4].

Tensile CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep measurements, such as those performed here, are covered by the ASTM D2990 and ISO 899-1 standards.

The CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep experiments were performed according to the Stepped IsothermalTests at controlled and constant temperature are called isothermal.Isothermal Method presented in [5], where the load is kept constant and the temperature is increased stepwise. This method is important for the accelerated testing of the long-term CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep behavior of polymer samples.

Experimental

The Material

The PE-HD samples used for these CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep experiments exhibit a bi-modal molecular structure. The bi-modal molecular structure of PE-HD is particularly relevant for detergent bottles due to its ability to provide an optimal balance of high strength, toughness, and environmental StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress crack resistance. This structure consists of a combination of short-chain and long-chain molecules, enhancing the material’s rigidity and impact resistance while maintaining flexibility. These properties make bi-modal PE-HD ideal for packaging aggressive chemicals and heavy liquids, such as detergents, that require durable and leak-proof containers.

The polymer samples were manufactured by twin screw extrusion as the initial step, followed by a drawing process resulting in sheets with a thickness of about 0.75 mm. From these, dog-bone-shaped samples were cut out along the machine direction, i.e., along the extrusion direction of the sheets. The thickness and width of the reduced section of the samples were approx. 0.75 mm and 4 mm, respectively. The length of the samples was controlled by the clamping length of the tension sample holder and was set to approx. 20 mm for all experiments.

DMA Measurements

The definition of the measurements was performed in the NETZSCH Proteus® DMA software. All parameters are summarized in table 1.

Table 1: Overview of the measurement parameters used for the DMA CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep experiments

ParameterValue
InstrumentDMA 303 Eplexor®
Measurement modeTension
Sample dimensions≈0.75 mm × ≈3.9 mm × 20 mm
AtmosphereStatic air

CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.Creep Measurement

TemperatureIsothermalTests at controlled and constant temperature are called isothermal.Isothermal at 25 ... 120°C (5°C steps, each step for 1 h)
Contact StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress1 MPa
Statical load typeStressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.Stress
Target value1 MPa (100 % limit)

Before the measurement series, a correction measurement was performed with empty crucibles to subtract from the sample measurements the heat-flow contribution and baseline effects stemming from the crucibles. The temperature and heat flow sensitivity calibration were performed with adamantane (C10H16), water, indium, bismuth and tin. All necessary parameters used for this experiment series are summarized in table 2.

Table 2: Overview of the measurement parameters used for the DSC experiments

ParameterValue
InstrumentDSC 214 Polyma
Sample mass≈10…12 mg
CrucibleAl Concavus®, 30 μl (pierce, cold welded)
Temperature interval-160°C ... 190°C
Atmosphere

N2 40 ml/min (purge 2)

N2 40 ml/min (protective)

Cooling deviceCC200LN2 cooling
Heating rate10 K/min
Cooling rate10 K/min

Measurement Results

DMA CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.Creep

The results of the CreepCreep describes a time and temperature dependent plastic deformation under a constant force. When a constant force is applied to a rubber compound, the initial deformation obtained due to the application of the force is not fixed. The deformation will increase with time.creep experiments for all three PE-HD polymers extruded for different numbers of cycles are summarized in figure 2. The black, red, and blue curves represent the data for the samples extruded one, three and seven times, respectively. The solid curves show the elongation of the sample as static StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain; the corresponding temperatures are displayed as dash-dotted curves.

In general, it can be observed that the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate increases with increasing temperature for all investigated polymers. In particular near the onset of the Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point, the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate increases significantly.

Far below the Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point of PE-HD, which is around 125°C to 135°C [7], there is a clear relationship between the creep resistance and the number of extrusion cycles. The more cycles the material has been through, the higher its creep resistance. At high temperatures, close to the Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point of PE-HD, the StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain rate for U0 x7 (blue curves) accelerates more with increasing temperature compared to U0 (black curves) and U0 x3 (red curves).

At the end of the IsothermalTests at controlled and constant temperature are called isothermal.isothermal step at 85°C (48000 s), the U0 sample shows a total StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain of 4.01%, the U0 x3 one of 3.70%, and the U0 x7 one of only 3.40%. At the end of the creep measurement at 120°C, the total StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain is nearly identical for the U0 x7 and U0 samples, with a total strain of 9.68% and 9.66%, respectively. The U0 x3 sample shows the best creep performance over the entire time/temperature program with a total strain of 9.28%. It should be noted that the thermal expansion plays a role in these stepwise temperature protocols as well. Thus, this factor needs to be taken into consideration when comparing the total strains for each of the samples at a given temperature.

Static strain, temperature, and stress data over time for U0, U0 x3, and U0 x7 samples in DMA 303 Eplexor analysis.
2) Static strain (solid curves), temperature (dash-dotted curves) and static StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress (dashed curves) as a function of time. The black, red and blue curves represent the data for the sample extruded one (U0), three (U0 x3) and seven times (U0 x7).

DSC Experiments

The results of the DSC measurements are shown in figure 3. All three samples display similar melting behavior. The average peak temperature of the melting event is at 137.4°C ± 0.3°C. However, there are minor differences that can be observed in the melting enthalpy and the shape of the melting event. As the amount of extrusion cycles increases, the total melting enthalpy drops from 204.5 J/g to 196.5 J/g. These values are in good agreement with the values of semicrystalline PE-HD [7]. Correspondingly, a lower crystalline fraction has been determined; it drops from 69.78% to 67.07%. The most striking difference is the shape of the melting event. All three samples show a convolution of two different distinct melting events. This manifests as a shoulder on the left side of the melting peak. With increasing extrusion cycles, the left shoulder appears to become more pronounced as the low molecular weight fraction increases.

Heat-flow curve analysis of PE-HD samples, showing DSC readings with peaks at 137.2°C for first heating runs.
3) Heat-flow curve of the three PE-HD samples as indicated. Only the first heating runs are shown. The curves have been shifted vertically along the DSC axis for better clarity.

Discussion

Two mechanisms are discussed in literature that can lead to a change in mechanical properties for scissoring and Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.crosslinking reactions. Regarding creep, polymers with a higher degree of crosslinking usually exhibit better creep resistance [3]. The results obtained here suggest that the improved creep resistance stems from crosslinking that is the dominant mechanism during repeated extrusion cycles. However, the sample extruded seven times, demonstrating optimal performance in the creep tests, showing lower creep resistance above 100-105°C compared to the other two samples. This might be related to the crystalline fraction within the samples. A lower Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point raises the homologous temperature.

In this regard, the DSC measurements reveal no change in the Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting temperature of any of the samples. However, distinct minor changes such as the lower melting enthalpy of U0 x7 and U0 x3 as well as the change in the shape of the melting event might account for the observed change in the creep behavior of the sample. The two overlapping EndothermicA sample transition or a reaction is endothermic if heat is needed for the conversion.endothermic melting events indicate a bimodal size distribution of the crystallites present in the polymers.

Above the Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition, but below the melting point of the polymers, the volume fraction of the amorphous microstructure determines the creep behavior. Based on the DMA creep results, it is possible that the polymer chains within the amorphous volume increasingly become more crosslinked with higher extrusion cycles. With increasing temperature, the volume fraction of the crystallites plays an increasingly important role in terms of the creep behavior. The DSC results suggest a lower volume fraction of crystallites present for the U0 x3 and U0 x7 samples. However, this depends on the size distribution of crystallites for each sample. Smaller crystallites tend to melt earlier than larger crystallites. Based on the melting events observed, the fraction of the lower-melting crystallites present in the samples increases with a higher number of extrusion cycles. Thus, at higher homologous temperatures, the low-melting crystallites have a growing influence on the creep behavior.

But an exact interpretation must be treated with caution, as it is difficult to draw certain conclusions without knowledge about the microstructure and the additives used within the polymer.

Conclusion

Most common thermoplastic polymers have a low melting point. This makes them susceptible to creep effects at ambient and elevated temperatures. When elevated temperatures occur, such as those in cars on hot summer days, one must be careful not to expose these products to such high temperatures for extended periods of time. Static forces from heavy weights (e.g., other consumer products) placed on the plastic products, combined with elevated temperatures, can cause creep in a short period of time. In the worst case, plastic bottles or other plastic products may lose their primary use function due to permanent deformation. It should be noted that creep also occurs at lower temperatures, but on a longer time scale.

Literature

  1. [1]
    “Plastic waste and recycling in the EU: facts and figures”. [Online]. Available at: https://www.europarl.europa.eu/topics/en/article/20181212STO21610/plastic-waste-and-recycling-in-the-eu-facts-and-figures
  2. [2]
  3. [3]
    Mendes, A.A., Cunha, A.M., and Bernardo, C.A., “Study of the degradation mechanisms of polyethylene during reprocessing”, Polym. Degrad. Stab., Bd. 96, Nr. 6, S. 1125–1133, 2011.
  4. [4]
    W. Korte, “Simulation of the Long-Term Behavior of Plastic Components”. [Online]. Available at: https://www.partengineering.com/en/blog/article/simulation-of-the-long-term-behavior-of-plastic-components
  5. [5]
  6. [6]
    “Polyethylen”. [Online]. Available at:https://de.wikipedia.org/wiki/Polyethylen
  7. [7]
AI Overview
An error occurred. Please try again.