11.04.2025 by Claire Strasser, Aileen Sammler

How Do You like Your Chocolate?

Chocolate Easter bunny with a bite taken out, surrounded by colorful eggs and a vibrant spring backdrop, evoking festive joy.

This is a Happy Easter blog article, describing how the temperature affects the mastication properties of chocolate.

With spring comes Easter – a time when chocolate is at the top of the shopping and eating list. ;-) That is why we ask you today: How do you like your chocolate? Straight from the fridge for a satisfying crunch? Or slightly warmer for a smoother mouthfeel?

You may have already noticed: The temperature of chocolate sig­nificantly influences the sensory experience during bit­ing and chewing. Here comes NETZSCH into play!

This sensory perception can be quantified using the axial capabilities of the Kinexus rotational rheometer equipped with a parallel plate geometry setup. A con­trolled downward and upward movement of the upper plate simulates jaw motion during mastication.

To illustrate this, we placed a piece of chocolate on the lower plate of the rheometer. The initial gap (distance between the upper and lower plates) was set to 3 mm. The upper plate then moved downward at a constant speed of 30 mm/s to a nominal gap of 1 mm before returning to its initial position. We recorded the normal force required for this movement, and this cycle was repeated one time. We conducted the test on chocolate at 10°C (refrigerated) and 35°C (mouth temperature).

Graph comparing the mastication simulation of chocolate at 10°C and 35°C, showing gap size and force metrics.
Figure 1: Simulation of mastication, performed on chocolate at 10°C (left) and at 35°C (right).
Graph showing the relationship between gap size and normal force during chocolate mastication tests at different temperatures.

Headline

What we found out:

Figure 1 shows the variation in gap size (blue curve) and the force required to reach it (orange curve). As expected, the higher the temperature, the more easily the chocolate is compressed. At 10°C, a force of 50 N resulted in a compression of only 150 μm, preventing the upper plate from reaching the target gap of 1 mm. In contrast, at 35°C, only 3.7 N was needed to compress the chocolate to 1 mm.

These results highlight the significant impact of tem­perature on the chewing sensation and emphasize the importance of proper storage for an optimal chocolate experience.

We hope you enjoy your chocolate and wish you Happy Easter!

Easter-themed cookie shaped like a rabbit, placed on a saucer next to colorful eggs and a flower, ideal for seasonal celebrations.